PCC-01004
Error: PCC-01004: In an EXEC statement at end-of-file
Causa: In a Pro*COBOL input file, the last EXEC statement was not terminated properly.
Acción: Terminate the last EXEC statement with an END-EXEC.
COMENTARIOS:
No hay comentarios.